LiteTouch has encountered an Environment Error (Boot into WinPE!)

After I disabled a couple of steps in the task sequence, I was confronted with this error that had me puzzled for a while. However it was not related to my changes. The deployment before the changes ended in errors and the clean-up didn’t finish all the way afterwards. When you start a new deployment it checks if a deployment is already in process on that computer. The harddrive had a partition with the folders minint and _SMSTaskSequence on it.

There are two ways to fix this issue:

Option 1:

  • Start into PXE and when the error is presented press F8
  • In the console type: diskpart
  • Type: select disk 0
  • Type: clean

Option 2:

  • Start into PXE and when the error is presented press F8
  • In the console type: c:
  • Type: format c: /Q
Be Sociable, Share!

Posted by Mischa Oudhof

Filed under: WDS/MDT Leave a comment
Comments (6) Trackbacks (0)
  1. Really really, thank you!! Option 1 worked like a charm!!

  2. Спасибо, очень помогло!)
    Thank you!)

  3. You.Are.A.Life.Saver. Thank you sooo much for posting this!!

  4. Worked a charm! Thanks muchly.


Leave a comment